Cross Talk Attenuator

Model No. : ACT

Specification:
Rectangular Cross Talk Sound Attenuators made of high quality 0.8 mm thick Galvanized Sheet with 100mm thick baffles consisting of 48 Kg/m3 density rockwool. Different specifications can be made to customer requirements based of sound attenuation requirements. Designed in U shape as standard and can be made in Z shape as option.

DESCRIPTION

  • Aerodynamically designed to ensure maximum insertion loss and minimal pressure drop. Air gap and length of silencer are selected to meet the required NC level.
  • Cross talk silencer is primarily used to reduce the noise interference between interconnected rooms while maintaining the smooth airflow with acceptable pressure drop level.
  • Sturdy construction and high noise absorbing capacity to obtain required insertion loss without compromising performance. Manufactured to ensure long and maintenance free service.
  • Splitters are V shaped at both ends to minimize self generated noise and pressure loss.
  • Duct mate flange or slip connection (standard) on both ends in compliance with DW144 standards.
  • Acoustic infill media is of superior quality non combustible & have fungi resistant characteristics meeting the requirements of EN ISO 1182 and ASTM C665 respectively. It has excellent noise reduction coefficient characteristics with an additional qualification of being biologically inert.
  • Optionally, Nitrile rubber/open cell insulation can be provided of required density and thickness.

PRODUCT ORDER CHECKLIST

To Design:

  • Required Room Sound Criteria
  • Airflow data for each silencer
  • Duct Size and maximum length available
  • Noise levels of air handling units

To Manufacture:

  • Size: W x H x L
  • Material: GI / Aluminium
  • Insulation Media and Density
  • Baffle Thickness
  • Airway Gap

INSTALLATION GUIDE

  • Allow at least 2-5 duct diameters in the upstream and downstream for better silencer efficiency.
  • Do not expose the silencer to dirt or excess humidity during installation or storage.
  • The HVAC system should be designed meticulously for proper dehumidification and air-filtration to prevent microbial growth within the silencer and the duct system.
  • It is recommended to install the silencer after the volume control damper to prevent regenerated noise.
    Don`t copy text!

    Etiam magna arcu, ullamcorper ut pulvinar et, ornare sit amet ligula. Aliquam vitae bibendum lorem. Cras id dui lectus. Pellentesque nec felis tristique urna lacinia sollicitudin ac ac ex. Maecenas mattis faucibus condimentum. Curabitur imperdiet felis at est posuere bibendum. Sed quis nulla tellus.