Circular Sound Attenuators

Model No. : ACL

Specification:
Circular Sound Attenuators made of high quality 1 mm thick Galvanized Sheet with baffles consisting of 48 Kg/m3 density rockwool. Different specifications can be made to customer requirements based of sound attenuation requirements.

DESCRIPTION

  • Circular silencer construction provides maximum acoustical performance, while minimizing system pressure drop even at high velocities. Desired aerodynamic performance is achieved by avoiding the need for square to round reducers that will increase the pressure drop.
  • Sturdy construction and high noise absorbing capacity to obtain required insertion loss without compromising performance. Manufactured to ensure long and maintenance free service.
  • Centre splitter (Pod) are radiused at both ends to minimize self generated noise and pressure loss.
  • Full width splitter in the middle and half width side splitters at the circumference.
  • Casing construction with lock formed seams meet SMACNA standards thus providing excellent strength and rigidity. Thoroughly sealed to prevent air leakage.
  • Slip connection on both ends in compliance with DW144 standards.
  • Acoustic infill media is of superior quality non combustible & have fungi resistant characteristics meeting the requirements of EN ISO 1182 and ASTM C665 respectively. It has excellent noise reduction coefficient characteristics with an additional qualification of being biologically inert.

PRODUCT ORDER CHECKLIST

To Design:

  • Required Room Sound Criteria
  • Airflow data for each silencer
  • Duct Size and maximum length available
  • Noise levels of air handling units

To Manufacture:

  • Size: D x L
  • Material: GI / Aluminium
  • Insulation Media and Density
  • Baffle Thickness
  • Airway Gap

INSTALLATION GUIDE

  • Allow at least 2-5 duct diameters in the upstream and downstream for better silencer efficiency.
  • Do not expose the silencer to dirt or excess humidity during installation or storage.
  • The HVAC system should be designed meticulously for proper dehumidification and air-filtration to prevent microbial growth within the silencer and the duct system.
  • It is recommended to install the silencer after the volume control damper to prevent regenerated noise.
    Don`t copy text!

    Etiam magna arcu, ullamcorper ut pulvinar et, ornare sit amet ligula. Aliquam vitae bibendum lorem. Cras id dui lectus. Pellentesque nec felis tristique urna lacinia sollicitudin ac ac ex. Maecenas mattis faucibus condimentum. Curabitur imperdiet felis at est posuere bibendum. Sed quis nulla tellus.

    ADDRESS

    63739 street lorem ipsum City, Country

    PHONE

    +12 (0) 345 678 9

    EMAIL

    info@company.com